Customization: | Available |
---|---|
After-sales Service: | Technical Support |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | EC-570S-P | EC-570SX-P |
Measurement principle | Fe: Magnetic induction; NFe: Eddy current effect | |
Measurement range | 0~3000μm | |
Accuracy | ±(2% reading+1μm), ≤2000μm ±(3% reading+2μm), 2001~3000μm ±(5% reading+2μm), >3000μm |
|
Resolution | 0.1μm(0~99.9μm); 1μm(≥100μm) | |
Unit | μm ,mm, mil | |
Iron powder putty identification range | 0~2000μm | |
Iron galvanized identification range | 3~1000μm | |
User calibration method | Zero calibration | |
Probe trigger force | 0.5~1.2N | |
Minimum radius of curvature of substrate | Convex 5mm; Concave 25mm | |
Minimum measurement area | Diameter 15mm | |
Minimum substrate thickness | Fe: 0.20mm; NFe: 0.03mm | |
Reaction time | <0.5 seconds | |
Display | Black and white LCD(128*48) + White OLED(128*32) | White OLED(128*64) + White OLED(128*32) |
USB data transfer | Support | |
Bluetooth and mobile APP | Support | |
Operating temperature | -10~+50ºC | -40~+50ºC |
Stored temperature | -20~+60ºC | -50ºC~+60ºC |
Power supply | 2pcs AAA 1.5V alkaline batteries(recommended) 2pcs AAA 1.2V Ni-MH batteries |
|
Protection class | IP40 | |
Dimensions | 101*64*25mm | |
Shell material | ABS | |
Weight | About 60g(without battery) |