Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 12 Months
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
R&D Capabilities
The supplier has 15 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
  • Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
  • Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
  • Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
  • Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
Find Similar Products
  • Overview
  • Specifications
  • Product Display
  • FAQ
Overview

Basic Info.

Model NO.
EC-600X
Type
Coating Thickness
Measurement Object
Thickness, Depth
Test Methods
Magnetic Induction, Eddy Current
Material
ABS
Precision Gauge
Precision Gauge
Certification
ISO, RoHS, CE
Usage
For Working, For Inspection, For Checking, Coating Measuring
Shape
Rectangular
Customized
Customization Accepted
Measuring Principle
Magnetic Induction & Eddy Currents
Probe
F & N External Probe
Measuring Range
0 to 2000 Um
Accuracy
+-(2%+1um)
Resolution
0.1um(0~100um); 1um(More Than 100um)
Calibration
Zero Calibration and Multi-Point Calibration
Units
mm, mm, Mil
Power Supply
2 PCS 1.5V AA Alkaline Batteries; 2 PCS 1.2V AA Re
Operation Environment
Temperature: -10~+50; Humidity: 20~90%Rh (Non-Con
Storage Environment
Temperature: -20~+50; Humidity: 20~90%Rh (Non-Con
Alarm
User Can Set The High/Low Alarm Limit; Alarm Icon
Display
128*48 DOT Matrix LCD Display, with Backlight
Dimensions
103*62*27mm
Readings Memory
10*13*10 Measurement Data
Standard Certification
CE,RoHS,ISO 2178,2360,GB/T 4956-2003,4957-2003,Jjg
Transport Package
Neutral Package
Specification
103*62*27mm
Trademark
YOWEXA/OEM
Origin
China
Production Capacity
20000pieces/Month

Product Description

EC-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters

Specifications

DESCRIPTION:
The series of EC-600 coating thickness gauges can be used to measure the thickness of non-conductive coatings on non-ferrous metals and non-magnetic insulating coatings on ferromagnetic metals (such as iron, nickel and cobalt, etc.). They are mainly used for non-destructive thickness measurement for the coatings of paint or galvanized layers on iron and stainless steel, paint or plastic film on aluminum and copper, etc.
EC-600 is with internal probe combined with magnetic induction and eddy currents principle, which is with measuring range of 0~2000μm and accuracy of ±(3%+1μm), and the highest resolution is up to 0.1μm.
EC-600 is only with one button, and it is easy to operate. When you start measurement, place the probe vertically and rapidly on a suitable surface, then the device will automatically distinguish the substrate material and measure the thickness of coatings.
EC-600X optimizes the principle on the basis of EC-600, and uses OLED display to enhance the low temperature working performance. Under the condition of using low temperature resistant battery, the extreme working temperature of EC-600X can reach -50ºC.
On the basic of EC-600, EC-600S is upgraded its probe and accuracy, and added new functions. The EC-600S is with stronger anti-interference ability compared with EC-600, and it can work in the high electromagnetic fields environment. The accuracy of EC-600S is ±(2%+1μm), and the measurement result can be sent to the mobile APP in real-time via bluetooth.
EC-600SE is with external probe version, the gauge can be equipped with a variety of separated probes for easy replacement. EC-600SE is better suited to work in narrower spaces or on assembly lines compared with EC-600S.

 

FEATURES:
 

 Ruby probe
 With Bluetooth and mobile APP
(EC-600S/SE)
Response time up to 0.3 seconds
Can work in low temperature as low as -40ºC (EC-600X)
 Resolution up to 0.1μm
• Accuracy ±(2%+1μm) (EC-600S/SE)
Measuring range 0~2000μm
• Display the maximum, minimum,
average and numbers of readings
Display interface can check back 10 measurement values
• Single button operation
• Zero calibration supported
External probe optional (EC-600SE)
• Dot matrix display
• Automatic shut-down
Battery protection

APPLICATION:
 

• Car paint thickness detection
• Shipbuilding
• Electroplating
• Metal anti-rust treatment
• Film thickness detection
• Hardware parts processing

 

 
Model EC-600 EC-600S EC-600SE EC-600X
Probe position Internal External Internal
Measuring principle Fe: Magnetic induction principle; NFe: Eddy currents principle
Measuring range 0~2000μm
Accuracy ±(3%+1μm) ±(2%+1μm) ±(2.5%+2μm)
Resolution 0.1μm(0~100μm); 1μm(>100μm)
Unit μm, mm, mil
Calibration Zero calibration
Probe Triggering force 0.5~1.2N
Minimum radius of curvature of substrate Convex 5mm
Concave 25mm
Minimum measurement area Diameter 15mm
Minimum substrate thickness   Fe: 0.30mm
NFe: 0.05mm
Fe: 0.20mm
NFe: 0.03mm
Fe: 0.30mm
NFe: 0.05mm
Response time About 0.3 seconds (upgrade)
Display Dot matrix LCD screen Dot matrix OLED screen
Bluetooth & APP N Y N
Operating environment -10~+50ºC -40~+50ºC
Storage environment -20~+60ºC -50~+60ºC
Power supply Two 1.5 V AAA Alkaline battery; Two 1.2V AAA rechargeable battery
Protection class IP40
Dimension 103*62*27mm Main Device: 103*62*27mm
Cable: Φ3.5*1000mm
Probe: Φ17*67mm
103*62*27mm
Material ABS Main Device: ABS
Probe: Stainless Steel
ABS
Weight About 57g
(not including battery)
About 112g 
(not including battery)
About 62g
(not including battery)
Standard   CE,ROHS,ISO 2178,2360,GB/T 4956-2003,4957-2003,JJG-818-2005

 

Product Display

Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth MetersYowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth MetersYowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth MetersYowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters

Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
Yowexa Ec-600X Ultra Low Temperature High Accuracy Coating Thickness Gauge Depth Meters
FAQ


Q. Do you make custom products?
A. Yes, we offer OEM/ODM solutions for our clients.
 

Q. How long is your lead time for samples?
A. 5-7 days. For bulk orders, 10-30 days depending on the quantity.
 

Q. What is your terms of payment?
A. 100% for small orders. 30% in advance as deposit and 70% balance before the delivery.
 

Q. How can we pay?
A. You can pay via T/T, PayPal and Western Union.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier