Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 1 Year
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
R&D Capabilities
The supplier has 15 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
  • Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
  • Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
  • Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
  • Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
Find Similar Products

Basic Info.

Model NO.
YEM-70L
Measuring Range
Medium-pressure Gauge
Type
Digital Display
Accuracy
1
Display
Digital
Application
Industrial, Civil
Structure
Digital Meter
Connection Type
Digital
Function
Local Indication Type, Electric Signal-controlled
Installation Structure
Stand
Features of Measurement Medium
General Pressure Gauge
Indicating Pressure Reference
General Pressure Gauge
Battery Life
1 Year(25ºC)
Standards/Certificates
Ce RoHS
Interface
Microusb
Transport Package
Carton
Specification
96X108X20mm/121g
Trademark
YOWEXA
Origin
Shenzhen China
Production Capacity
50000PCS/Year

Product Description

room air pressure temperature and humidity monitor for hospital and laboratory 
Product Overview
Environment Meters With U-Disk Data Logger

· Generate txt/csv/xls data logger file without any software and driver
· Used as u-disk on
PC to download data logger file easily
· Support professional software to view the 
graph and analyze data
· User can set logging interval and file output type by button
· View history maximum/minimum/average
· High/low alarm user configurable
· Real-time and history alarm status indications
· Calendar supported and user configurable
· Sound alarm supported
· Large LCD display with backlight
· Comfort level indications
· ºC/ºF/Dew point
· Battery status indication and long battery life

 
Wide Range Of Application

· Home                                  · School                                   · Hospital                                    
· Station                                · Laboratory                           · Shopping Mall
 
Specification
 
Model YEM-40C YEM-40CL
Measurement Parameters Temperature(dry ball, dew point), Humidity, Carbon Dioxide
Recording Function None Yes
Unit Temperature:ºC, ºF; Humidity:%RH; Carbon Dioxide:PPM
Measuring Range Temperature: -30~+ 65ºC(built-in probe); -40~+125ºC(external probe);
Humidity: 0~100%RH(Non-condensation)
Carbon Dioxide: 0 ~ 10,000PPM
Measuring Accuracy Temperature: ±0.5ºC(-10~ +65ºC); ±1.0ºC(Other Range)
Humidity: ±5%RH(10~90%RH, 25ºC); ±6%RH(Others)
Carbon Dioxide: ±3%±40PPM (400~2000PPM,0~50ºC); (Other ranges shown for reference only)
Resolution Temperature: 0.1ºC
Humidity: 0.1%RH
Carbon Dioxide: 1PPM
Response Time(t90) Temperature: 15 minutes(built-in probe); 5 minutes(external probe)
Humidity: 15 minutes(built-in probe); 5 minutes(external probe)
Carbon Dioxide: ≥3 minutes
Measuring Interval Temperature: 5 seconds
Humidity: 5 seconds
Carbon Dioxide: 5 seconds~30 minutes adjustable    
Temperature: 5 seconds
Humidity: 5 seconds
Carbon Dioxide: 5 seconds~120 minutes adjustable
Recording Interval None 5 seconds~120 minutes adjustable
LCD Refresh Interval 5 seconds
Storage Capacity None 22,528 Data points per channel
Operating Temperature 0~+50ºC
Storage Temperature -30~ + 65ºC (no batteries)
Battery 3 pcs 1.5V AAA alkaline batteries (USB power supply is recommended)
Power Supply Interface Micro USB,DC 5V/2A
Protection Class IP20
Overall Dimensions 108*96*20mm
Housing Material ABS
Weight About 124g (no batteries)
 
More Pictures

Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
Room Air Pressure Temperature and Humidity Monitor for Hospital and Laboratory
 
Why Us?
  1. From raw materials to final products, we have a strict quality control system. Our defective rate is about 0.1%.
  2. Our staff is well-trained and educated in this industry, we will save money in the end because of our efficiency and know-how.
  3. We have been in business for 10 years and thanks to our R&D department, we always catch the latest trend in the market.
  4. With the required certificate and experience after-sales service, there was no issue in the shipment we have arranged.  
  5. We have rich experience in handling orders for heavy buyers with the professional process.
       •  Stable raw material purchasing
       •  Favorable order follow-up management
       •  Laudable lead-time & shipment control
       •  Traceable quality evaluation
       •  Flexible payment terms
       •  Remarkable after-sale service
    6. Innovative testing technology is always pursued and to do.
       •  We are first to create the LED display rotated and red backlight alarm in the world.
       •  We are the first one create menu operations for coating thickness gauges in China.  
       •  Software: Dgraph can be so easily used to set up, download data, view graph and output reports.
 

Send your message to this supplier